Ordering the wrong implant component is one of the most expensive small mistakes a lab can make. The part itself may not cost much, but the delay does: a case sits on the shelf, the doctor reschedules the patient, and a technician spends time on calls instead of design. Almost every wrong order traces back to one missing detail on the prescription or one assumption nobody checked.
This checklist is meant to sit next to the person who places orders. Work through it for every implant case before you click buy. If you want background on how compatible components fit into the market, see our IPD implant components compatibility overview.
1. Implant manufacturer, system and line
“Nobel” or “Straumann” is not enough. Manufacturers run several implant lines with different connections, and the components are not interchangeable between lines. A Straumann Bone Level implant and a Straumann BLX implant, for example, need different components. The same goes for the various Nobel Biocare, Astra, Biomet 3i, BioHorizons and Neodent lines.
- Ask the clinic for the implant sticker, surgical record or chart entry, not a guess from the radiograph.
- Record the exact line name on the work order.
- If the record is missing, stop and ask. Do not order on a hunch.
2. Platform and connection size
Within one line, the connection usually comes in more than one platform size, and names vary: narrow, regular and wide platforms, or diameter labels such as D-3.5 or D-4.3. Component listings, including IPD’s, typically name the platform. The platform is not always the same as the implant body diameter, so match the component to the connection the manufacturer specifies, not to a measurement you take yourself.
3. Engaging or non-engaging
This choice comes from the restoration design:
- Single-unit restorations generally use an engaging component, so the indexed connection prevents rotation.
- Splinted, multi-implant restorations often use non-engaging components, because engaging indexes on several implants with different angles may not all seat along one path of insertion.
Check that the scan body, the Ti base or abutment, and the analog all agree with the design. A non-engaging Ti base on a single crown is a rotation problem waiting to happen; an engaging base on a splinted bridge may never seat.
4. Gingival height and abutment height
Ti bases and abutments come in different gingival (collar) heights, and some come in different post or chimney heights. The right choice depends on soft-tissue depth, the planned emergence profile and the restorative space. Too short a collar puts the bonded interface deep in the tissue; too tall a collar can leave metal visible or crowd the restoration.
Measure tissue depth from the scan or the model, decide the height during design planning, and write it on the order. IPD custom Ti bases, for example, are listed by gingival height (GH), and scan abutments come in more than one height.
5. Angle and access
If the implant is angled, decide early how you will deal with it. Options include angled multi-unit abutments (commonly offered in angles such as 17 and 30 degrees), custom abutments, or a design that moves the screw access to an acceptable position. Each option changes what you need to order. Multi-unit cases have their own checklist; our article on multi-unit abutment workflows goes through them.
6. Screw type and driver
Every component is designed to work with a specific screw. Confirm:
- The screw matches the component and platform. Screws that look alike can differ in thread, length or head seat.
- Lab screw vs final screw. Many labs use a separate screw for fabrication and try-in, and send a new final screw with the case. Mark them clearly so they are never mixed.
- Coatings and head type. Some screws are offered with coatings or particular drive types. Order what the restorative plan calls for.
- The driver. The clinic needs the matching driver. If the drive type is unusual for that office, flag it.
Torque values are the implant manufacturer’s and the dentist’s call. Do not put a torque value on the case paperwork unless it comes from them.
7. Digital or physical analog
Printed models need digital analogs designed to be pressed or bonded into a printed socket. Stone models need conventional analogs set in gypsum. The two are not interchangeable, and a digital analog also has to match the model-design library you used to create its socket. Our guide to digital vs physical analogs covers the fit and accuracy details.
8. Scan body and CAD library compatibility
This is the step most often skipped, and the one that causes the worst surprises. Before ordering:
- Confirm the scan body the clinic used (or will use) is in your CAD software’s implant library.
- Confirm the Ti base or abutment you plan to order is in the same library, paired with that scan body.
- If you print models, confirm the digital analog is in the model library as well.
- Check that your library version is current. A missing or outdated library entry can mean a design you cannot complete, or one that is subtly wrong.
If any piece is missing from the library, resolve it before the clinic scans, not after.
9. Quantity and spares
- One component and one analog per implant site.
- A spare screw for each site is cheap insurance.
- For a lab that sees the same systems repeatedly, keep a small stock of the most common scan abutments, Ti bases and screws.
10. Document the order
Write the manufacturer, line, platform, engaging or non-engaging, heights, angle, screw and analog type on the work order, along with the part numbers you ordered. When a question comes back from the clinic weeks later, that record answers it in seconds.
A quick pre-order summary
- Implant manufacturer, system and line confirmed from records
- Platform or connection size confirmed
- Engaging or non-engaging matches the restoration design
- Gingival height and abutment height chosen
- Angle correction planned
- Correct screw (lab and final) and driver
- Digital or physical analog matches the model type and library
- Scan body, Ti base and analog all present in the CAD library
- Quantities and spares counted
- Part numbers recorded on the work order
Implant components in our catalog
Our implant components category includes IPD Dental Group parts organized by implant system and component type: scan abutments in engaging and non-engaging versions, custom Ti bases listed by gingival height, temporary abutments, straight and angled multi-unit abutments, screws, and both digital and physical analogs. Examples include the Straumann Bone Level digital analog D-4.1, the Nobel Biocare Active / Replace CC 17° multi-unit abutment and the Astra OsseoSpeed engaging scan abutment. We also stock Elemental-brand multi-unit digital analogs and multi-unit screws. Check each listing’s compatibility details against your case before ordering.